Level-crossing barrier
+7 (499) 266-69-96
Address
1–33, plot 1, Letchika Babushkina str., Moscow, Russia, 129344

Level-crossing barrier



Scope and field of application

Barriers fully comply with the technical requirements of TU 32 CSh 2069-99. They are designed to block off train sections at level crossings with motorways, thus preventing vehicles from driving onto crossings.
These barriers may be used in temperate climates (U) with location category 1 according to GOST 15150-69. Barriers may be supplied with a signal head that emits light or sound signals or without it.
Download detailed information

Main technical features

Barrier arm opening time   12 sec 
Distance between lowered arm and motor level  1,000 - 1,250 
Arm length from the axis of rotation  4.0; 6.0; 8.0 
Opened barrier arm angle  80:900 
Electric drive AC power supply voltage  220 + 10% V 
Electromagnetic clutch power supply voltage  12 (-0.6/+1.2) V 
Signal head AC or DC power supply voltage   12 -1,5 V 
Crossing bell DC power supply voltage  12 (+5/-2) V
Electric motor power consumption  0.25 kW 
Electromagnetic clutch power consumption  30 W 
One LED signal head power consumption  25 W 
Dimensions 5,000; 7,000; 9,000 mm - length;
1,265; 1,295; 1,385 mm - width;
2,520 mm - height with a signal head;
1,080 mm - height without a signal head 
Weight (for barrier arms of 4; 6; 8 m)  277; 322; 430 kg - with a signal head;
230; 285;383 kg - without a signal barrier